液壓搖臂鉆立柱夾不緊故障及排除
原因分析:彈簧3上的螺釘調(diào)的太多,使立柱抬得太多,菱形塊夾緊機(jī)構(gòu)不能是內(nèi)外立柱結(jié)合的錐面壓緊;調(diào)整螺母6調(diào)的不適當(dāng),使杠桿13與殼體之間產(chǎn)生間隙;液壓系統(tǒng)中的壓力油太小,不能推動(dòng)油缸立的活塞,是菱形塊不能處于夾緊的位置。
排除方法:重新調(diào)整彈簧板上的螺釘,但要保證搖臂松開(kāi)時(shí)的作用力,再調(diào)整柱頂上的螺母使其夾緊力達(dá)到1568n(在搖臂末端的推力)再用螺釘鎖緊螺母;如果立柱松開(kāi)時(shí)較輕,要調(diào)整螺母6,減少杠桿與殼體間的間隙,再將其上面的螺母7中的4個(gè)螺釘緊固;調(diào)整液壓系統(tǒng)中的壓力油保證在245-291x10000pa或更換油池中的機(jī)油。
備注:螺釘、螺母見(jiàn)使用說(shuō)明書(shū)標(biāo)注
文章引用:
搖臂夾緊調(diào)整
主軸箱夾緊
hydraulic rocker drilling column clamp tight and troubleshooting
cause analysis: spring 3 screws on the tune too much, so that the upright post too much, rhombic block clamping mechanism cannot be inside and outside column with conical compression; adjusting nut 6 adjustable inappropriate, so that the lever 13 and the shell creates a gap between; hydraulic system in the oil pressure is too small, cannot push oil cylinder set the piston is rhombic block, not in the clamping position.
elimination: reset spring board by screws, but to ensure that the rocker arm during a release of the force, and then adjust the column on the nut so that the clamping force to reach 1568n ( in the arm end thrust ) and then screw locknut; if the column is released is light, to adjusting nut 6, reduce the gap between the lever and the housing, then the nut 7 of 4 screws; adjusting hydraulic system of pressure oil assurance in 245-291x10000pa or replace the oil in the oil tank.
note: screws, nuts see manual annotation